Low -voltage series

DK6211-G low-voltage circuit measurement and control terminal-guide orbit formula

DK6211-G low-voltage circuit measurement and control terminal-guide orbit formula

Low Voltage Loop Measurement and Control Terminal -Guide Rail Type

Low -voltage circuit measurement and control terminals meet the standard design of the south network V3.0,Realize high -precision voltage、current、power、Calculation and display of data measurement such as power volume,Dynamic alarm is achieved by setting multiple sets of limited values.,Complete short circuit、overload、Lack of phase、phase preface、Failure to zero and other fault judgment functions。Alarm and opening the position to generate a SOE event,and can pass CAN、RS485 interface to achieve remote letter、Active active for remote test、Passive delivery,Combination with the fusion terminal can be implemented, plug -and -play function。 Low -voltage circuit measurement and control terminal can be used for intelligent power distribution rooms、branch switch、Line detection and control of the scene of intelligent power distribution box scene。

execution standard

Execution Standard

◆ GB/T 14598.9 electromagnetic compatibility test and measurement technology radiation electromagnetic field interference test

◆ GB/T 14598.10 electromagnetic compatibility test and measurement technology electric fast instantaneous pulse group antipity test

◆ GB/T 14598.14 electromagnetic compatibility test and measurement technology static discharge resistance test

◆ GB/T 14598.13 electromagnetic compatibility test and measurement technology pulse interference test

◆ GB/T 17626.6 Electromagnetic compatibility test and measurement technology radio frequency field sensor's conduction harassment resistance test

◆ GB/T 17626.5 electromagnetic compatibility test and measurement technology wave (impact) antipity test

◆ GB/T 17626.8 Electromagnetic compatibility test and measure the antipity test of the technical frequency magnetic field

◆ GB/T 17626.9 Electromagnetic compatibility test and measurement technology pulse magnetic field resistance test

◆ GB4208-1993 Shell Protection Level (IP code)

 

Function features

Functional Features

Basic measurement

three -phase voltage and average value、Three -phase current and average、Three phases have power and total value、Three -phase powerless power and total value、Three -phase view at power and total value、Wiring diagnosis、Frequency、Zero -order current calculation。

Fixed value is limited

At most 9 groups of fixed value,Monitoring voltage、current、Zero -order current、Frequency、Total power、None power、Visates in power、Total power factor、There are always merits of real -time demand、Total harmonic distortion、Elementary degree and other variables,Can produce a remote letter or event、Trigger relay action。

Wiring diagnosis

voltage/current deficiency diagnosis、voltage/current phase sequence diagnosis、There is a total power direction diagnosis;

Frequency Exception Monitor、Short circuit、overload、Failure to zero and other fault judgment。

Electricity Measurement and Frozen

Have the function of power measurement and demand statistics,and support the power electrophoresis、No exercise electrical pulse output;

Daily frozen: 60 days,Monthly frozen: 12 months。Electricity of the device、Required data, etc. For freezing,Record freezing data and freezing time。

Communication interface

RS485: 2 Road。MODBUS -RTU protocol,The communication rate can be configured;

Can Communication: 1 Road。 MODBUS -RTU protocol;

Wireless Communication: 1 (optional).

Performance parameters and indicators

Performance Parameters and Indicators

Product features

Simple wiring,Only one CAN bus is required to complete the interaction with the upper machine data;

Built -in power supply, small volume, easy to install;

Support is plug and play technology

Performance indicators

AC sampling accuracy 0.2 level

Yinxin resolution 2ms

Measurement accuracy is 1 level 1, level 2

2 RS485 serial port

1 CAN

The power consumption of the whole machine & le; 2va

After power outage, the supercapacitance power supply for 30 seconds

Product Manual


Simple version of the product instructions:DK6211-G (L) -The guide-simple version instructions

Full Version Product Manual:DK6211-G (L) -The guide-the full version instructions

Modbus Detailed communication point link:Low -voltage circuit Surveying and Control Terminal Modbus point
execution standard
Function features
Performance parameters

Back to top